{"id":7376,"date":"2024-06-03T16:20:44","date_gmt":"2024-06-03T16:20:44","guid":{"rendered":"https:\/\/neuropediatoolkit.org\/?p=7376"},"modified":"2026-11-01T07:36:21","modified_gmt":"2026-11-01T07:36:21","slug":"bis","status":"publish","type":"post","link":"https:\/\/neuropediatoolkit.org\/en\/bis\/","title":{"rendered":"BIS."},"content":{"rendered":"<h2 class=\"wp-block-heading\">BIS Monitor: Brief Clinical Guide<\/h2>\n<p class=\"wp-block-paragraph\">The BIS Monitor (Bispectral Index) is a neurological monitoring tool that estimates the state of consciousness through analysis of brain activity from electroencephalographic (EEG) signals. It does not directly measure consciousness, but rather the depth of anesthetic hypnosis.<\/p>\n\n<figure class=\"wp-block-image aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" width=\"662\" height=\"386\" src=\"https:\/\/neuropediatoolkit.org\/wp-content\/uploads\/2024\/06\/bis-1.png\" alt=\"Esquema de funcionamiento del BIS: sensores en el cr\u00e1neo, an\u00e1lisis de EEG, salida num\u00e9rica.\" class=\"wp-image-7378\" srcset=\"https:\/\/neuropediatoolkit.org\/wp-content\/uploads\/2024\/06\/bis-1.png 662w, https:\/\/neuropediatoolkit.org\/wp-content\/uploads\/2024\/06\/bis-1-300x175.png 300w, https:\/\/neuropediatoolkit.org\/wp-content\/uploads\/2024\/06\/bis-1-18x10.png 18w\" sizes=\"(max-width: 662px) 100vw, 662px\" \/><figcaption>The BIS uses sensors in the skull to analyze EEG patterns and generate an index between 0 and 100, with lower values \u200b\u200bindicating greater depth of anesthesia.<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">BIS Classification and Clinical Significance<\/h3>\n<ul class=\"wp-block-list\">\n  <li><strong>BIS 0\u201325:<\/strong> Deep coma; minimal brain activity. Incompatible with conscience.<\/li>\n  <li><strong>BIS 26\u201375:<\/strong> Intermediate coma state; response to inconsistent stimulation.<\/li>\n  <li><strong>BIS 76\u2013100:<\/strong> Normal consciousness; high and stable brain activity.<\/li>\n<\/ul>\n\n<figure class=\"wp-block-image aligncenter\"><img decoding=\"async\" width=\"600\" height=\"621\" src=\"https:\/\/neuropediatoolkit.org\/wp-content\/uploads\/2024\/06\/bis-2.png\" alt=\"Gr\u00e1fico de valores BIS en tiempo real durante cirug\u00eda: fluctuaciones con ajustes anest\u00e9sicos.\" class=\"wp-image-7377\" srcset=\"https:\/\/neuropediatoolkit.org\/wp-content\/uploads\/2024\/06\/bis-2.png 600w, https:\/\/neuropediatoolkit.org\/wp-content\/uploads\/2024\/06\/bis-2-290x300.png 290w, https:\/\/neuropediatoolkit.org\/wp-content\/uploads\/2024\/06\/bis-2-12x12.png 12w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><figcaption>Real-time BIS values \u200b\u200ballow anesthetic dose to be adjusted. Sharp drops (e.g. from 70 to 20) indicate deep hypnosis, requiring adjustment.<\/figcaption><\/figure>\n\n<h3 class=\"wp-block-heading\">Clinical Use and Limitations<\/h3>\n<ul class=\"wp-block-list\">\n  <li>Recommended in general anesthesia, especially in neurosurgery or patients with neurological disease.<\/li>\n  <li>Values <50 sugieren p\u00e9rdida de consciencia;>60 indicates a normal state of consciousness.<\/li>\n  <li>It does not replace the Glasgow Coma Scale (GCS). A low BIS does not necessarily imply low GCS if the patient responds to stimuli.<\/li>\n  <li>In pediatrics, adjustments are required: children may show greater variability in BIS due to greater sensitivity to the anesthetic.<\/li>\n<\/ul>\n\n\n<div id=\"wp-block-themeisle-blocks-accordion-efd92130\" class=\"wp-block-themeisle-blocks-accordion exclusive\">\n<details class=\"wp-block-themeisle-blocks-accordion-item\"><summary class=\"wp-block-themeisle-blocks-accordion-item__title\"><div>Clinical Alert: Common Misinterpretation<\/div><\/summary><div class=\"wp-block-themeisle-blocks-accordion-item__content\"><p class=\"wp-block-paragraph\">Confusing BIS with GCS may lead to underestimation of neurological status. A patient with BIS 40 may have GCS 15 if they respond to stimuli. The BIS assesses underlying brain activity, not behavioral response.<\/p>\n\n<\/details><\/div><\/details>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>Keys to apply:<\/strong> Maintain BIS between 70\u201380 in non-neurological surgeries; adjust dose if BIS drops &lt;50. Always consider age, type of procedure and clinical context.<\/p>","protected":false},"excerpt":{"rendered":"<p>BIS Monitor: Brief Clinical Guide The BIS Monitor (Bispectral Index) is a neurological monitoring tool that estimates the state of consciousness through analysis of brain activity from electroencephalographic (EEG) signals. It does not directly measure consciousness, but rather the depth of anesthetic hypnosis. BIS Classification and Clinical Significance BIS 0\u201325: Deep coma; \u2026 <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/neuropediatoolkit.org\/en\/bis\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> \"BIS.\"<\/span><\/a><\/p>","protected":false},"author":1,"featured_media":7379,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_themeisle_gutenberg_block_has_review":false,"footnotes":""},"categories":[79],"tags":[],"class_list":["post-7376","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-neurouci","entry"],"_links":{"self":[{"href":"https:\/\/neuropediatoolkit.org\/en\/wp-json\/wp\/v2\/posts\/7376","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/neuropediatoolkit.org\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/neuropediatoolkit.org\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/neuropediatoolkit.org\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/neuropediatoolkit.org\/en\/wp-json\/wp\/v2\/comments?post=7376"}],"version-history":[{"count":7,"href":"https:\/\/neuropediatoolkit.org\/en\/wp-json\/wp\/v2\/posts\/7376\/revisions"}],"predecessor-version":[{"id":9022,"href":"https:\/\/neuropediatoolkit.org\/en\/wp-json\/wp\/v2\/posts\/7376\/revisions\/9022"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/neuropediatoolkit.org\/en\/wp-json\/wp\/v2\/media\/7379"}],"wp:attachment":[{"href":"https:\/\/neuropediatoolkit.org\/en\/wp-json\/wp\/v2\/media?parent=7376"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/neuropediatoolkit.org\/en\/wp-json\/wp\/v2\/categories?post=7376"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/neuropediatoolkit.org\/en\/wp-json\/wp\/v2\/tags?post=7376"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}